POOL SPA HELP

 

 

 

 

 

BBB

 



 

 

On a 120v 20 amp. connection or a 220v. 30 amp connection, the heater will turn off when the pump is on high speed because there is not enough electricity to run the heater and the high speed pump at the same time. On a 220v. 50 amp connection, the heater will remain on when the high speed pump is turned on because there is enough electricity to run both at the same time.

The following is for a qualified person who

has read the disclaimer (click here). Power to Spa Pack

must be turned OFF at breaker box and

checked with a voltage meter to be sure power

is OFF. Please follow diagram below


MINUS THE RED WIRE, THE PICTURE BELOW SHOWS THE CONNECTIONS FOR A 120v 20 amp SETUP.

 

 

 

 


STEP 2 - For 220v. 50 amp conversion, remove the yellow wire from the "low speed" connection on the tree,

and connect it to the "hot load" connection on the tree.

 

 

  

HOT TUB SPA REPAIR - HOT TUB SPA EQUIPMENT - HOT TUB SPA PACKS - HOT TUB SPA PARTS

POOL REPAIR - POOL EQUIPMENT - POOL VINYL LINERS - ABOUT US - INDEX